Conductive Level Controller. 61F-GP-N8. Compact Plug-in Level Controllers for Single or Two-point Level Control of Conductive. Materials (Liquids and Solids). N: 11 pins. N8: 8 pins. Blank: General-purpose. L 2KM: Long-distance (for 2 km) 61F-GP-NH High-sensitivity Controller uses advanced operation. When the. Omron 61F-GP-N8 - Pdf User Manuals. View online or download Omron 61F-GP- N8 - Manual.


61f Gp N8 Pdf

Author:KIMBERLEE SCHURE
Language:English, Portuguese, Dutch
Country:Japan
Genre:Biography
Pages:295
Published (Last):04.02.2016
ISBN:335-9-73817-193-5
ePub File Size:24.69 MB
PDF File Size:14.70 MB
Distribution:Free* [*Sign up for free]
Downloads:46776
Uploaded by: SUZANNE

61F-GP-N8 AC from OMRON >> Specification: Liquid Level Controller, 61F- GP Series, Floatless, DPDT, Vac, VA, 80 ms. CE marking (N and N8 models) and UL/CSA compliance The relay in the 61F- GP-NH de-energizes when there is water present across the Electrodes. 61F-GP-N8 AC Description. LEVEL CONTROLLER. Manufacturer. Omron. Series. 61Fr. Type. Level Control - General Purposer. Datasheets. greavargesnado.cf .

Output type: Contact and NPN transistor output. Supply voltage: to VAC.

Highly visible display with backlit transmissive LCD. Provides a total and preset counter, batch counter, dual counter, and tachometer See note. Operating method: ncrementing and decrementing selectable with DIP switch. Mounting method: Flush mounting.

Input signal method Count and reset inputs : Contact and transistor input, voltage H and L. Memory backup: No.

Display: Yes mm high 7-segment LED. Models: 4 digits. A draw-out construction enables maintenance without rewiring. Models with 2-, 4-, 6-, or 8-digit displays are also available.

The water provides a current between the earth probe and the high-level probe. The output relay in the Controller is energized when the water level reaches the high-level probe and de-energized when the water level falls below it.

For two-point control a low-level probe is used as well. In this case the relay does not de-energize until the water level falls below the low-level probe.

Using the low-level probe allows a wide differential between switching a pump on and off, and can avoid excessive pump operation during tank emptying or filling. If this differential is not required, the low-level probe need not be connected. When connecting the Surge Suppressor Unit, wire as shown in the following example with three electrodes. Mount the Surge Suppressor Unit as close to the Controller as possible.

Mounting Holes 4 dia. Dust preventive rubber cap optional Note: Standard holder construction includes three integral mm-long electrodes. However, a model having 1,mm-long electrodes is available on request. Two, 6-dia. Three, 7 dia.

Mounting Holes Two, M4 or 4. Two, 3. PFC-N8 Approx. Tighten the electrode with the two clamp screws. Connecting nut 1.

Spin a lock nut and a spring washer onto the electrode. Spring washer 4.

61F-GP-N[]

Secure the connecting nut by tightening the lock nut and spring washer. Lock nut 2. Fully fit the electrode into the connecting nut attached to the electrode holder.

Fully fit the electrode into the Spring washer connecting nut Connecting nut attached to the electrode holder. Spring washer 3.

Cuir Iarratas ar Fhocail

Ice bank control in cold drink dispensers, ice makers, water chillers, bulk milk tanks, etc. Indication of liquid buildup due to filter blockages. Alarm control warning of abnormal or dangerously high or low levels.

Application When using electrodes in sea water or sewage, provide a sufficient interval normally 1 m between the electrodes. If the sufficient interval cannot be provided, employ a low-sensitivity-type Floatless Level Controller.

When taping one of the electrodes to prevent it from contacting the other electrodes in water, do not tape the electrode entirely but leave at least mm of its end uncovered. When the required length of the electrode is more than 1 m, use a separator at each joint of two electrodes so as to prevent the electrodes from contacting one another.

Note: Avoid use of the separators in dust-containing liquids.

61F-GP-N8-V50 230AC : 61FGPN8V50230AC Specification

Usually, electrodes are used in a set of three: long, medium, and short. Connect the short electrode to E1, the medium electrode to E2, and the long electrode to E3. Make E3 at least 50 mm longer than E2.

You might also like: WAGON TIPPLER EBOOK DOWNLOAD

Standard electrodes are made of stainless steel and usable in purified water, sea water, sewage, acid except acetic acid, sulfuric acid, etc. To convert millimeters into inches, multiply by 0.Fully fit the electrode into the connecting nut attached to the electrode holder.

Catalogue sheets

Solid-state Alternate Operation Relay When operating two pumps alternately for controlling the one-point liquid level, use the Relay in combination with 61F Controller. PDF ; Readbag users suggest that Tighten the electrode with the two clamp screws. Weight Approx. Fully fit the electrode into the Spring washer connecting nut Connecting nut attached to the electrode holder.